Thermocouple Sealed Feedthroughs
Thermocouple Sealed feedthroughs are available from stock or on a short lead time.
Whether you require 1,2,3,4,5,6,7 sealed thermocouples or more, we will have a solution for you. Types J, K, N and T are all available.
Whatever your Thermocouple Sealed feedthrough requirement, please contact our team today by clicking the blue enquiry button below.
Thermocouple Sealed Feedthroughs
Thermocouple sealed feedthroughs are available from Jacarem from stock or on very short lead times:
- Thermocouple sealed feedthrough – 1 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 2 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 3 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 4 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 5 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 6 x wire – Types J, K, N, T
- Thermocouple sealed feedthrough – 7 x wire – Types J, K, N, T
In addition to these most popular standard items, we have a range of other thermocouple sealed feedthroughs as well as a lot of custom parts.
Thermocouple Sealed Feedthrough Testing
Most importantly, 100% of parts are checked for quality. These checks include: dimensional inspection, helium leak test, 1000 PSI test, an electrical hipot 300 VDC 300 MOhms and visual workmanship.
Leak tested for 1 ATM 10X10^-8 STD-CC/SEC leak rate or better.
Seal operating temperature -20C to 130C (wire temperature rating is 250C).
We have a wide selection of other thermocouple sealed feedthroughs that have been previously manufactured, so if the above standard items don’t cover your requirements, please contact us. If it is a thermocouple sealed feedthrough that hasn’t been made before, we are able to design and arrange manufacture to your exact requirements within any flange size. Alternatively, we can make custom seals, so please let us know exactly what you require.
Finally, for further information or a quotation for Thermocouple sealed feedthroughs, please contact us.
Enquire About Thermocouple Sealed Feedthroughs
"*" indicates required fields
If you would like further information about Thermocouple Sealed Feedthroughs, a sample or a quotation, please contact: [email protected] or phone 01494 791336. Our sales team will be happy to assist you with your project.